BZPNQ - 150 LP SOLVENT NEUTRAL

Product Identification

Product ID:150 LP SOLVENT NEUTRAL
MSDS Date:09/15/1993
FSC:9150
NIIN:01-399-4843
MSDS Number: BZPNQ

Responsible Party
EXXON CO USA, A DIV OF EXXON CORP.
800 BELL ST
HOUSTON, TX 77252-2180
US

Emergency Phone: 713-656-3424 800-424-9300(CHEMTREC)

Info Phone: 713-656-3424 800-443-9966

Cage: 29700

Contractor
EXXON COMPANY U.S.A.
2180 HOUSTON, TX 77252-2180 US

Telephone: 713-656-5949 / 713-656-3424

Cage: 29700

Ingredients

OIL CONSISTING OF INGREDIENTS 1 AND 2

Fraction By Weight: 100%


MINERAL OIL, PETROLEUM DISTILLATES,HYDROTREATED

CAS: 64742-54-7

RTECS: PY8035500

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


MINERAL OIL, PETROLEUM DISTILLATE, SOLVENT DEWAXED (MILD),

CAS: 64742-65-0

RTECS: PY8038500

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT) IS >5G/KG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:MAY CAUSE IRRITATION.SKIN:MAY
CAUSE IRRITATION AND DEFATTING.INGEST:MAY CAUSE GI TRACT
IRRITATION.ASPIRATION HAZARD.INHAL:MAY CAUSE RESPIRATORY
IRRITATION.
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:SKIN:DERMATITIS.HIGH PRESSURE INJECTIONS MAY
APPEAR TO BE INSIGNIFICANT,HOWEVER,THIS IS A MEDICAL EMERGENCY.
Medical Cond Aggravated by Exposure:MANUFACTURER STATES NONE.

First Aid

First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH SOAP AND
WATER.HIGH PRESSURE INJECTON UNDER THE SKIN IS A MEDICAL
AEMERGENCY.EYES:FLUSH WITH WATER FOR 15 MINUTES.CALL PHYSICIAN IF
IRRITATION PERSISTS.INHA L:REMOVE TO FRESH AIR.GIVE OXYGEN OR
ARTIFICIAL RESPIRATION IF NEEDED.INGEST:DO NOT INDUCE VOMITING.GET
PROMPT QUALIFIED MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:COC
Flash Point:399F,204C
Autoignition Temp:Autoignition Temp Text:>500F
Extinguishing Media:WATER FOG,DRY CHEMICAL,CARBON DIOXIDE,FOAM AND
VAPORIZING LIQUIDS EXTINGUISHANTS.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.COOL FIRE EXPOSED CONTAINERS WITH WATER
FOG.
Unusual Fire/Explosion Hazard:FIRE CONDITIONS MAY EVOLVE TOXIC FUMES.

Accidental Release

Spill Release Procedures:SOAK UP WITH NON-COMBUSTIBLE INERT
ADSORBANT(EG.CLAY);PLACE COLLECTED MATERIAL IN AN APPROPRIATE
CONTAINER FOR DISPOSAL;CLEAN SPILL AREA TO REMOVE
SLIPPERINESS.AVOID CONTAMINATION OF GROUND OR WATERCO URSES.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
PLACE.KEEP CONTAINER CLOSED WHEN NOT IN USE.KEEP AWAY FROM
HEAT,SPARKS,FLAMES AND INCOMPATIBLE MATERIALS.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation:LOCAL VENTILATION AT THE WORKSITE;MECHANICAL(GENERAL)
VENTILATION TO MAINTAIN TLV/PEL.USE NON-SPARKING EQUIPMNT.
Protective Gloves:CHEMICALLY RESISTANT GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING,AS NEEDED.PROVIDE A
LOCAL EYE WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:USE REASONABLE CARE IN HANDLING THIS
PRODUCT.WASH HANDS AFTER USE AND BEFORE EATING.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:556F,291C
Melt/Freeze Pt:M.P/F.P Text:-0F,-18C
Vapor Pres:0.01
Vapor Density:>5
Spec Gravity:0.87
Viscosity:156SSU 100F
Evaporation Rate & Reference:>0.01 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:OIL.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS(EG.LIQUID CHLORINE,CONCENTRATED OXYGEN,SODIUM
OR CALCIUM HYPOCHLORITE).
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE,CARBON MONOXIDESULFUR
OXIDES,ALDEHYDES AND UNIDENTIFIED COMPOUNDS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.